Corrente primária nominal(A) | Combinação de classes de precisão | Classe de precisão e potência de saída nominal(VA) | 4 Segundo a corrente térmica(KA/1S) | Corrente dinâmico nominal(KA) | |
50 |
0, 2/0, 2/0, 2
0, 2/0, , 5/0, 5 0.5/0., 5/0, 5 0, 2/0, 2/10P10 0, 2/0, 5/10P10 0.5/0.5/10P10 0.2/10P10/10P10 0.5/10P10/10P10 10P10/10P10/10P10 0, 2/0, 2/0.2/10P10 0, 2/0, , 5/0.5/10P10 0.5/0., 5/0.5/10P10 0, 2/0, 2/10P10/10P10 0, 2/0, 5/10P10/10P10 0.5/0.5/10P10/10P10 0.2/10P10/10P01/10P10 0.5/10P10/10P10/10P10 10P10/10P10/10P10/10P10 |
0.2 | 15 | 3 | 7.5 |
0.5 | 25 | ||||
10P10 | 50 | ||||
75 | 0.2 | 15 | 5 | 12.5 | |
0.5 | 25 | ||||
10P10 | 50 | ||||
100 | 0.2 | 15 | 8 | 20 | |
0.5 | 25 | ||||
10P10 | 50 | ||||
31.5 | 0.2 | 15 | 12 | 30 | |
0.5 | 25 | ||||
10P10 | 50 | ||||
200 | 0.2 | 15 | 16 | 40 | |
0.5 | 25 | ||||
10P10 | 50 | ||||
300, 400 | 0.2 | 15 | 20 | 50 | |
0.5 | 25 | ||||
10P10 | 50 |