General specifications
|
Item |
Specification |
||
|
Basic specification |
Carrier frequency |
0.5k ~ 16k(Hz) ; Carrier frequency can be adjusted automatically according to the load characteristic. |
|
|
Input frequency resolution |
Data setting : 0.01Hz Analog setting : highest frequency×0.1% |
||
|
Output frequency accuracy |
Data setting : highest frequency×±0.01% Analog setting : highest frequency×±0.01% |
||
|
Control mode |
Split-ring vector control (SVC)/ Closed loop vector control (VC) |
||
|
Startup torque |
0.5Hz/180% ( SVC ); 0Hz/200% ( VC ) |
||
|
Speed control range |
1 : 100 ( SVC ) |
1 : 1000 ( VC ) |
|
|
Speed accuracy |
±0.5% ( SVC ) |
±0.05% ( VC ) |
|
|
Overload capability |
150% rated current for 60 seconds; 180% rated current for 1 second. |
||
|
Speed up and speed down curve |
Straight line or S curve acceleration and deceleration way ; 4 group acceleration and deceleration time and S curve settings; various combinations |
||
|
Testing and mending control |
Can be appointed by any multi-stage speed |
||
|
Multi-stage running |
Realize at least 8 stage speed |
||
|
Automatic voltage regulation ( AVR ) |
Keep output voltage permanent, when network voltage changes |
||
|
Display and operation |
LED display |
Display setting frequency, output frequency, output voltage, output current and other parameters |
|
|
LCD display operating panel |
Choose parts, operation tips in Chinese/English |
||
|
Parameter copy |
LCD operating panel makes a copy of parameters quickly |
||
|
Protection function |
Provide 40 kinds of protection such as electrify short circuit survey, in-out lack phase protection, over current protection, over voltager protection, undervoltage protection etc. |
||
|
Key lock and function choosing |
Set partial or complete lock of the keys; define function range of part of the keys to avoid misoperation |
||
|
Special function |
Electrify peripheral equipment safety self-examination |
Implement electrify and do peripheral equipment detection like grounding, short circuit etc. |
|
|
Blackout emeegency function |
The realization of emergency project is easy and convenient |
||
|
Over speed protection |
Elevatoe over speed protection function built in; various operation choices |
||
|
Judgment of speed deviation |
Speed deviation testing function built in to find out potential risks in time |
||
|
Forced speed changing function |
Effectively avoid hoisting and resting of the elevator |
||
|
Motor temperature testing |
Judge the temperature of the motor in time and eliminate potential risks |
||
|
Startup compensation |
Two ways of startup torque compensation ; analogue or digit |
||
|
QUICK key |
Customers can define shortcut menu freely |
||
|
Timing control |
Convenient for timing |
||
|
Input/output characteristi |
Running order channel |
Three channels : decided by operation panel, control terminal, communication |
|
|
Frequency source |
Five frequency source : decided by digit, analogue voltage, analogue current, communication, multi-stage speed |
||
|
Input terminal |
10-path digit input terminal, 1 path of it can be used as high-speed pulse input, which is compatible to PNP or NPN 3-path analogue input terminal, 1 path of it can only be used as voltage input, another one can be used as voltage or current input. |
||
|
Output terminal |
3-path digit output terminal 2-path relay output terminal 2-path analogue output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be chosen , can realize the output of setting frequency, output frequency and other physical quantities |
||
|
Circumstance |
Altitude |
Lower than 1000 meters |
|
|
Surrounding temperature |
-10 ºC ~+ 40 ºC ( when within 40 ºC ~ 50 ºC , derating is required ) |
||
|
Humidity |
Less than 95%RH , no condensation |
||
|
Vibration |
Less than 5.9 m/s² ( 0.6g ) |
||
|
Storage temperature |
-20 ºC ~+ 60 ºC |
||